Boiler Treatment Chemicals
Contact Now:
Prime Specialities
#6-3-652 D/28, 203, 2nd Floor,
Dhruvatara, Amrutha Estate,
Somajiguda, Hyderabad,
Telangana, India.
Pin Code-500082.
Phone: 040–40055050,
040–40202121
Email: web@primespl.com
All in One
These are simple solution which takes care of complete boiler feed water, controls hardness, prevents scale formation and corrosion of metal by controlling pH. It also contains sludge conditioners and oxygen scavengers.
|
|||||||||
Hardness Conditioners
When added to boiler feed water in proper concentrations, these products prevent calcium scale by precipitation of the preferred hydroxyapatite. A special polymeric sludge conditioner is included in the blend to fluidize the precipitate and make it non-adherent.
PRODUCT CODE |
KEY CHARACTERISTIC |
APPLICATION |
COROGARD 214 |
Prevent scale formation in boilers |
Hardness conditioner |
COROGARD 218 |
All in one to maintain heat transfer surface clean and high efficiency |
Corrosion & Scale inhibitors |
Oxygen Scavengers
These products prevent oxygen corrosion in boilers, economizers, pumps and feed-water lines by chemically removing the last traces of oxygen from feed water. Oxygen scavengers will also reduce certain types of turbine deposits and provide residual effectiveness for protecting boilers during wet standby.
PRODUCT CODE |
KEY CHARACTERISTIC |
APPLICATION |
COROGARD 210 |
Liquid Oxygen scavenger for high pressure boilers |
Removes dissolved oxygen from boiler feed water suitable for |
COROGARD 212 |
Liquid Oxygen scavenger for low Pressure boilers |
Removes dissolved oxygen from boiler feed water suitable for low- |
COROGARD 213 |
Liquid Oxygen scavenger for low Pressure boilers |
Removes dissolved oxygen from boiler feed water for low pressure |
ROTOZINE 100 |
Organic catalyst based Hydrazine |
Removes dissolved oxygen from boiler feed water suitable for |
ROTOZINE 101 |
In-organic catalyst based Hydrazine |
Removes dissolved oxygen from boiler feed water suitable for |
Alkalinity builders
These product increase the pH by neutralizing dissolved CO2 present in the feed / condensate. Alkaline pH is necessary for good control of metal loss.
PRODUCT CODE |
KEY CHARACTERISTIC |
APPLICATION |
COROGARD 234 |
pH Booster / Alkalinity builder |
To maintain pH in boiler water |
Condensate Conditioners
To provide complete protection against corrosion in steam condensate systems, we have developed both filming and neutralizing corrosion inhibitors. When added to boiler feed water, filming corrosion inhibitors volatize with the steam and are carried to all parts of the system where they form a non-wet table, protective film on all metal surfaces. This film prevents dissolved oxygen and / or carbon dioxide corrosion by acting as a water proof barrier between metal and condensate. Neutralizing inhibitors also volatize and travel with the steam. When condensation occurs, they neutralized CO2, elevating the PH of the condensate. In essence, filming inhibitors are used to treat the metal in the system while neutralizing inhibitors treat the water flowing through it.
PRODUCT CODE |
KEY CHARACTERISTIC |
APPLICATION |
COROGARD 300 |
Condensate conditioner for pH and scale preventive film |
For high pressure boilers like paper mills and petrochemical refinery |
COROGARD 301 |
Condensate conditioner for pH and scale preventive film |
For high pressure boilers like paper mills and petrochemical refinery |
Neutralizing Amine Based
PRODUCT CODE |
KEY CHARACTERISTIC |
APPLICATION |
COROGARD 310 |
pH control of condensate |
For low pressure boilers |
COROGARD 311 |
pH control of condensate |
For high pressure boilers |
Sludge Conditioners
They prevent adherence of sludge formed in the boiler.
|
|||||||||
Descalants
We offer ROTO KLEEN range of cleaners / descalant for heat
exchangers systems to increase heat transfer.
|
|||||||||